Basic Info.
- Function: Storage of cryogenic liquid
- Type: Double layer metal wall
- Storage Medium: LC2H4, Liquid Ethylene
- Structure: Full containment

Product Parameters
|
Design Code |
• "Design and Construction of Large Welded Low-Pressure Storage Tanks" (API 620) |
|
|
• "Design and Manufacture of Site Built, Vertical, Cylindrical Flat-bottomed Steel Vessels for the Storage of Cryogenic Liquefied Gas" (GB/T26978-2021) |
||
|
• "Storage Tank Systems for Refrigerated Liquefied Gas" (API 625) |
||
|
• "Welded Tanks for Oil Storage" (API 650) |
||
|
Type |
Double layer metal wall |
|
|
Insulation Type |
perlite + elastic felt + cellular glass insulation blocks + glass wool |
|
|
Design Temperature |
Primary container |
-196/+50℃ |
|
Secondary container |
-196/+50℃ |
|
|
Design Pressure |
Primary container |
25/-0.5kPa |
|
Secondary container |
1.0/-0.5kPa |
|
|
Working Pressure |
15kPa or customized |
|
|
The Main Material |
Inner Vessel |
S30408/SA-240 Grade 304 |
|
Outer Shell |
S30408/SA-240 Grade 304 |
|
|
Volume |
10000m³≤V≤100000 m³ or Customized Size |
|
|
Static Evaporation Rate |
≤ 0.08% /d (Liquid Ethylene) |
|
|
Core Components |
Primary container, Secondary container, Thermal corner protect layer, Insulation system, Pipeline, Tower ladder & steel structure, Valves & Instruments, Firefighting system. |
|
|
Supply State |
Prefabricated material supply, on-site installation |
|
|
Color |
Customized / Standard [white] |
|
|
Painting |
Primer coat (Prefabricated) + intermediate coat + topcoat (on-site) |
|
|
Design Service Life |
20years |
|
|
Mode Of Transportation |
Road, Sea or Railway |
|
Technical Requirements
- With high safety and sealing, it can ensure the safety of storage and prevent accidents, widely used in petrochemical and other fields.
- We design our cryogenic liquid flat-bottom storage tanks with double- wall steel structures using high tech insulating materials (perlite + elastic felt + cellular glass insulation block + glass wool).
- Insulation layer at the bottom, interlayer, and top: between baseplate of primary container and secondary container is filled high-efficiency thermal insulation materials (cellular glass insulation block, concrete ring beams); the wall plate interlayer between the primary container and the secondary container is filled with perlite; glass wool is placed on the suspended roof to reduce the loss caused by liquefied gas evaporation.
- Steel structure platform and ladder: The primary container is equipped with straight ladder to facilitate the installation and commissioning of equipment; the top is equipped with operation platform to meet the daily operation of valves and instruments; the secondary container wall is equipped with tower ladder to meet the daily inspection and emergency evacuation needs of operators.
- Pipeline and valve system: used for ethylene loading and unloading, transportation, and maintaining pressure balance inside the container to ensure safe operation.
Company Profile

Suzhou Doer Gas & Chemical Equipment Co.,Ltd. is a high-tech enterprise, whose businesscovers R&D, design, manufacture, installation, complete engineering and industrial servicesof cryogenic equipment. Doer's total factoryarea is 135,000㎡ and the company has morethan 600 employees, including over 90 designand research & development professionals. Dedicated to becoming a leader in the field ofcryogenic liquid storage and transportation, DOER strives to provide clients with one-stopprofessional services.