Basic Info.
- Function: Storage Cryogenic liquid
- Type: Vertical or Horizontal
- Storage Medium: Liquid Helium

Product Parameters
|
Design Code |
ASME Boiler and Pressure Vessel Code Section VIII Division 1 -2023; |
|
|
GB/T150.1~4-2024 "Pressure Vessels"; |
||
|
T/CCGA 20015-2024 |
||
|
Type |
Vertical or Horizontal |
|
|
Insulation Type |
High Vacuum Multilayer Insulation with Liquid Nitrogen Shield |
|
|
Design Temperature |
Inner Vessel |
-269℃ |
|
LN2 Vessel |
-196℃ |
|
|
Outer Shell |
50℃ |
|
|
Max. Working Pressure |
Accept Customized Pressure |
|
|
Conventional Pressure Level |
0.1MPa≤P≤1.2MPa |
|
|
Working Pressure |
0.1~1.2MPa or customized |
|
|
The Main Material |
Inner Vessel |
06Cr19Ni10N |
|
LN2 Vessel |
06Cr19Ni10 |
|
|
Outer Shell |
Q345R |
|
|
Effective Volume |
10m3≤V≤250 m3 |
|
|
Filling Rate |
87% |
|
|
Color |
Customized / Standard [white] |
|
|
Painting |
Primer + intermediate coat + topcoat (3 layers) |
|
|
Design Service Life |
20years |
|
|
Warranty |
1 Year |
|
|
Transport Package |
Nude, saddle support |
|
Technical Requirements
- The design, manufacturing and inspection of vacuum storage tank mainly according to T/CCGA 20015-2024 "Technical Specifications for the Safe Use of Liquid Helium Storage Tanks", and can also follow international standards such as ASME.
- The inner vessel is used to store liquid helium, and the shell material is austenitic stainless steel, which has good low temperature resistance. The shell plays a protective role and provides reliable protection for the interlayer insulation material and vacuum degree.
- The interlayer adopts high vacuum multi-layer insulation with liquid nitrogen shield. Multiple layers of alternating combination of spacer materials and reflective screens are set up in the interlayer space, and a cold shield for storing liquid nitrogen is set up to greatly reduce heat intrusion and lower the evaporation rate of liquid helium, ensuring long-term storage.
- The storage tank is equipped with stainless steel cryogenic globe valve, combined vacuum valve (including vacuum gauge to measure the vacuum degree of the insulation layer at any time), safety valve, relief device, pressure gauge, liquid level gauge and other valve instruments;
- The inner vessel is equipped with two sets of independent over-pressure relief devices to effectively ensure the safety of the tank. In addition, the safety explosion-proof devices installed on the outer vessel further ensure the safety and reliability of the entire equipment.
- For the inner vessel of the storage tank, 100% Radiographic Testing (RT) is first performed on Category A and Category B welded joints. This is followed by 100% Penetrant Testing (PT) on all welded joints. After ensuring that the non-destructive testing results are qualified, a pneumatic test is conducted on the inner vessel. Finally, each weld and joint is subjected to a leak test using a helium mass spectrometer leak detector.
- The finished paint film on the outer surface of the storage tank is dense, firm and reliable, and the dry film thickness of the paint is greater than 200 µm.
- The tank needs to be replaced with nitrogen before leaving the factory. Fill the interior of the liquid container with 0.03~ 0.05Mpa pressure nitrogen gas for protection.
- The liquid helium high vacuum storage tank is easy to install and has low maintenance costs. It is mainly used in aerospace, semiconductor, cutting-edge scientific research, medical and other high-tech industries and fields.
Application scope of fixed liquid storage tanks

Technical Requirements
The LHe High Vacuum Storage Tank facilitates cryogenic cooling for superconducting systems (MRI/NMR, ITER) and quantum computing dilution refrigerators.

Medical & Life Sciences
The LHe High Vacuum Storage Tank supports cryogenic biobanking (stem cells, vaccines, organs) and supplies helium for large MRI systems in medical facilities.

Industrial & Aerospace Applications
The LHe High Vacuum Storage Tank enables vacuum chamber cooling for EUV lithography in semiconductor manufacturing and ultra-low temperature simulation for aerospace components like satellites and rocket engines.

Energy & Nuclear Technology
The LHe High Vacuum Storage Tank supports pre-cooling and steady-state cooling for ITER fusion reactors and provides cryogenic maintenance for experimental high-temperature superconducting (HTS) grid energy storage systems.
Company Profile

Suzhou Doer Gas & Chemical Equipment Co.,Ltd. is a high-tech enterprise, whose businesscovers R&D, design, manufacture, installation, complete engineering and industrial servicesof cryogenic equipment. Doer's total factoryarea is 135,000㎡ and the company has morethan 600 employees, including over 90 designand research & development professionals. Dedicated to becoming a leader in the field ofcryogenic liquid storage and transportation, DOER strives to provide clients with one-stopprofessional services.
Certifications

Customer visiting

FAQ
Hot Tags: lhe high vacuum storage tank, China lhe high vacuum storage tank manufacturers, factory